EZ-CAL Flow Cell (Lightpath: 1-100mm)

EZ-Cal 1.png
EZ-Cal 2.png
EZ-Cal 3.png
EZ-Cal 4.png
EZ-Cal 1.png
EZ-Cal 2.png
EZ-Cal 3.png
EZ-Cal 4.png

EZ-CAL Flow Cell (Lightpath: 1-100mm)

$5,899.00

High-pressure (2000psi) fiber optic flow cells in a ⅜” configuration with adjustable lightpaths. For use in demanding industrial environments. Features a slot where users can place a FireflySci NIST-traceable calibration standard

Spectral properties can be measured when used in conjunction with Optical Interface Couplers. Comes standard with UV Quartz couplers. Connects to any photometric analyzer via SMA-905 connections.

The Dual EZ-CAL Flow Cell can also be configured with two independent pathlengths.

Quantity:
Add To Cart

CAD Drawings:

Advantages of EZ-CAL Flow Cell:

  1. Reduced valving requirements

  2. No zero or span valves (3 way’s)

  3. No waste stream from zero/span gases or liquids to dispose of

  4. No possibility of either sample or reference carryover into flow cell

  5. Reduced risk of leaks because there are fewer fittings/tubing to deal with

  6. Reduced dependence on Reference material

Advantages for gas applications

  • No cylinder requirement

  • No pressure regulator requirement

  • No cylinder shut off valves to contend with

  • No cylinder stratification to contend with

  • No cylinder temperature issues to contend with

Advantages for Liquid applications

  • No liquid standards to deal with

  • No worries that the standards have changed over time

  • No worries that the reference container is full or empty

  • No worries about what to do with spent reference material

  • No dependence on lab to make liquid samples

  • Reduced risk of leaks from fittings 

Main reasons to switch to the EZ-CAL system

  1. Reduced overall cost (reduced hardware costs and reduced size, weight, shipping costs)

  2. Reduced overall risks to safety

  3. Standards can be solid or sealed cuvette filled primary or secondary NIST traceable

  4. Standards can be solid ND filters with various absorbances, colored glass (for vis) filters, UV or NIR specific customized filters

  5. Standards can be purchased from several sources

  6. Standards will all fit into a standard 10mm block that is integrated into the EZ-CAL flow cell

  7. If handled properly, standards can be used over and over

  8. Standards can be “re-certified” by a 3rd party for validation purposes

  9. Standards can be carried into the field, inserted into the flow cell and then brought back to the engineering department or lab

  10. Customer never exposes him/her-self to toxic, carcinogenic or explosive samples

  11. Calibrations/validations are performed via “calibration by standard addition”

Standard Specifications

⅜” CROSS FLOW CELL

  • Lightpath: adjustable 1-100mm

  • Body material: 316 Stainless Steel

  • Pressure rating: 2,000psi

  • Standard Optical interface couplers: UV Quartz (190-2,500nm)

  • Various reference/optical filters can be easily inserted into the optical path of the flow cell to add a fixed amount of absorbance to your instrument’s baseline.

  • Photometric/spectrophotometric validation/calibration without shutting down the process or introducing gases or liquids into the process stream.

  • Reference materials can be liquid or solid NIST traceable standards.

Additional Configurations:

A= Body Material

  • 316SS

  • Titanium

  • Hastelloy C 276

  • Monel

  • Other

B= Connection

  • 1/2” Sanitary

  • 3/8” Compression

  • 1/4” VCO

C= OIC Lens

  • Fused Silica

  • Sapphire

D= OIC Window

  • Fused Silica

  • Sapphire

E= OIC Seal

  • Viton

  • Kalrez

  • Chemraz

FGH= Pathlength

  • 0.25-50mm

EZ Cal Flow Cell Video:

How to Adjust Lightpath with Optical Interface Couplers

How to Set and Determine the Optical Pathlength:

Procedure for Pathlength Adjustment - Determination.png